All inspection services are carried out to industry standard specs to include
API RP-7G-1, API 5A- 5C, API SPEC-7
DS-1 CAT 2 TO 5
NS-1 CAT 2 TO 5
All inspectors are qualified to minimum ASNT-level 2, for EMI, MPI, DIE-PEN, EDDY CURRENT, U/T.
Certification and eye test certificates are available and are regularly, monitored and retested as required by ASNT
NEW TECH, Techscope EZW-11tm system, 3 units
This system is an industry proven design and is high speed, very durable for field work, the tranverse flaw detection system is extremely accurate and the units are equipped with a Hall effect true wall monitoring, the units are set up quickly and are calibrated at site using the calibration joints provided for each size of pipe that is inspected.
Pipe sizes are 2 3/8” to 6 5/8”
GE Krautkramer USN-60 digital ultrasonic flaw detection unit
U/T inspection shear wave method, with multi probe heads for the end areas of drill pipe
BHA BLACK LIGHT MPI units, 7 units.
Standard MPI units for MPI of BHA assembly’s, and drilling tools and equipment, each kit is provided with magnetizing / de-mag coils to ensure correct levels of magnetized material, and after inspection these are de-magnetized.
Also provided with AC yoke and accories for MPI inspection on other equipment.
Die penetrate kits are also included in these kits for the inspection of non carbon steel equipment
Field type re-facing equipment is also included with each unit
Full length drifting with Teflon drifts or steel drifts to all sizes and weights
SEA inspection of couplings and ends
VTI inspection
Full length EMI inspection of tubing to 5” OD
Wall thickness verification